Vet1 Multiparameter Monitors

FLOLINE W SERIES

Floline W12/W15 Series Animal Monitor

The W12/W15 high-end animal-specific modular monitor is designed to meet the growing demand for animal healthcare, modular customization, and diverse clinical applications, allowing the animal world to enjoy high-end life care.

Dedicated veterinary algorithm

LowPulseStrTM SPO2 algorithm more reliable readings of SPO2 during low perfusion and motion.
iFastBP® NIBP algorithm used for fast and comfortable measurement.
wSmartHeart® ECG technology for more safey monitoring of patient.
wSmartGas® Capnograph technology to get reliable reading during multi-environment.

Powerful function

Plug-in module, multiple parameters available.
12.1,15.6-inch screen can be optional.
Wifi connectivity more flexible application.
eTeleViewTM Central Monitor system support.
Smart alarm system more safety and more efficient.
Fanless design.

Fully Modular & Upgradable

Sidestream CO2+2IBP+CO
Sidestream CO2+2IBP
Sidestream CO2
Mainstream CO2
Tini Stream CO2
2IBP+CO
2IBP

Floline VM800 Series Animal Monitor

The VM800 high-end Veterinary Specific Monitor is designed to meet the growing demand of animal healthcare. Enjoy the same high-end Modules as our W12 & W15, but in a smaller version with an 8”
Touch Screen.

Dedicated veterinary algorithm

LowPulseStrTM SPO2 algorithm more reliable readings of SPO2 during low perfusion and motion.
iFastBP® NIBP algorithm used for fast and comfortable measurement.
wSmartHeart® ECG technology for more safey monitoring of patient.
wSmartGas® Capnograph technology to get reliable reading during multi-environment.

Powerful function

 Plug-in ETCO2 parameter available.

• 8” Touch Screen

• Wi-Fi connectivity more flexible application. (Optional)

• eTeleView Central Monitor system support. (Optional)

• Smart alarm system more safety and more efficient.

• Fanless design.

ETCO2 Plug & Play Modules (Optional)

ETCO2 (Tinistream)

ETCO2 (Mainstream)

Specifications

Standard Configuration Optional Configuration
• 3 Lead ECG • 5 Lead ECG
• NIBP • Wifi
• RESP • Central Monitoring
• SPO2
• PR
• HR
• TEMP
• Touch Screen
• Printer

SPO2
• SPO2Range: 0~100%
• SPO2Accuracy: 70~100%, ±2%
• PIRange: 0~20%
• PVIRange: 0.001%
• PRRange: 25-350bpm
• PRAccuracy: ±3bpm

ECG
• ECGRange: 0.15~5.5mV
• ECGResolution: 2.36uV/LSB
• HRRange: 15~350bpm
• HRAccuracy: ±1bpmor±1%
• RRRange: 0~120bpm
• RRAccuracy: 15~120rpm: ±2rpm or ±2%

RESP
• Range: 0-120Rpm
• Accuracy: 15-120Rpm ±2Rpmor±2%
• Resolution: 1Rpm

TEMP
Range: 0-50°C
Accuracy: ±0.1°C
Resolution: 0.1°C

NIBP

Pressure Range: 0~300mmHg
Pressure Accuracy: ±2mmHg or±1%of reading (take the larger value)
Resolution: 1mmHg

SYS Range:
Large animal:40-270mmHg
Medium animal: 40-235mmHg
Small animal: 25-130mmHg

DIA Range:
Large animal: 10-210mmHg
Medium animal: 10-180mmHg
Small animal: 10-90mmHg

Mean Range:
Large animal: 20-230mmHg
Medium animal: 20-200mmHg
Small animal: 15-100mmHg

Accuracy:The mean deviation<±5mmHg
The standard deviation<8mmHg
Supplied with 5 x Premium Reusable Cuffs

Veterinary Capnography Basics

Watch on Youtube Now